This section makes frequent use of data contained in the Technical Requirements.

All relevant sections of the Technical Requirements Data collection should be completed or known before commencing with the steps in this section.

Create API User

VSM requires a user account to be created on Ribbon Edge SBC, in order to run API commands which collect status of Edge SBC.

Ribbon Edge SBC users can be created via one of two options:

  1. Local User Option
  2. Active Directory Option
  3. RADIUS User Option


Local User Option

Browse to SBC then Navigate to Security > Users > Local User Management



Click on (plus) icon to create new user

Fill in the required user details as per the table below

FieldValueMandatory/optional
User NameEnter Username to be used by VSMMandatory
PasswordEnter PasswordMandatory
Confirm PasswordEnter Password againMandatory
Access LevelRESTMandatory



Active Directory User Option

This option is applicable only if Active Directory is integrated with Ribbon Edge SBC .

Create New User on Active Directory (Ask Active Directory Administrator) to create User for Ribbon SBC.

Active Directory Administrator need to make sure the new Ribbon SBC user is in the correct Group that will have API Access.

Confirm with Active Directory Administrator AD Group Name.

Browse to SBC then Navigate to Security > Users > Remote Auth Permission > AD User Group

Click (plus) to create AD User Group to Access Level Mapping



Fill in the required fields as below 

FieldValueMandatory / optional
Group NameSpecifies the name of a valid Active Directory user group to which a SBC Edge access level is assignedMandatory
Access LevelSelect REST from the drop downMandatory


Additional Details can be found here

RADIUS User Option

This option is applicable only if RADIUS Server  is used to manage Ribbon Edge SBC Users

Create New User on RADIUS Server  (Ask RADIUS Server Administrator) to create User for Ribbon SBC

Check with RADIUS Server Administrator User Class name for the newly created user

Browse to SBC then Navigate to Security > Users > Remote Auth Permission > RADIUS User Class


Click User to Access Level and Click (plus) icon


Fill in the required fields as below 

FieldValueMandatory / optional
Group NameSpecifies the name of RADIUS class to which a SBC Edge access level is assigned ,Class Name is case sensitive and must match the RADIUS class exactlyMandatory
Access LevelSelect REST from the drop downMandatory

Additional Details can be found here

Ribbon SBC Edge SNMP Configuration

SNMP configuration is required as part of Ribbon SBC Edge Monitoring . SNMP can be configured as  V2, or V3 based on customer requirements.

Browse to SBC then Navigate to SNMP/Alarms > SNMP Management Address

Click the (plus) icon to to add New SNMP Manager Address


SNMP Version 2 Option

Fill in the required fields as below

FieldValueMandatory / Optional
Manager AddressEnter IP Address of VSM ProbeMandatory
SNMP VersionSelect Version 2 From the drop downMandatory
CommunityEnter the Community StringMandatory
Community TypeRead-OnlyMandatory
Trap EnabledTrueMandatory


SNMP Version 3 Option


Fill in the Fields as below:

FieldValueMandatory / Optional
Manager AddressEnter IP Address of VSM ProbeMandatory
SNMP VersionSelect Version 3 from the drop downMandatory
Community TypeRead-onlyMandatory
USM User NameEnter SNMP UsernameMandatory
Auth ProtocolSelect any of the options (None , MD5 or SHA 1Mandatory
Auth PasswordEnter Auth Password - applicable only if selected Auth Protocol is MD5 or SHA1Mandatory
Confirm Auth PasswordRepeat Auth password entered above to confirmMandatory
Priv Protocol

AES 128 must be selected if Auth Protocol is set to anything other than None,

Otherwise None can be selected

Mandatory
Priv Password

Enter Privacy Password.

Hidden when Priv Protocol is set to None

Mandatory
Confirm Priv PasswordRepeat password entered above to confirmMandatory
Trap EnabledSelect True from Drop DownMandatory


Additional details can be found here


Web Portal Configuration

Add Ribbon SBC Edge (Swe Lite ,1000 , 2000)

Log in to the VSM web portal using your VSM credentials and password.

For your customer, select Service Desk > Equipment Locations. Right-click on the Equipment Location that will serve this particular Ribbon Edge SBC and select ‘Manage Equipment’

At the bottom of the ‘Manage Equipment’ page click on the ‘Add Equipment’ button.

A form will open which you can populate with the equipment details as per table the table below

Select the Vendor 'Ribbon Communications' and Product 'SWe Lite, 1000, 2000 (Edge Series)'



Web Portal – Add Ribbon SBC Edge Field Description

Field

Setting

Vendor

Ribbon Communication

Product

'SWe Lite, 1000, 2000 (Edge Series)'

Equipment Name

Friendly name for this SBC

API Username

API Username

API Password

API Password

IP Address / Host Name

IP Address of SBC

Site

Free text field, this information will be included in alarm notifications from the VSM Workflow.

SNMP

Complete the Equipment tab and then click on the ‘SNMP Query’ tab.

Click on the down arrow, and select the SNMP version you wish VSM to use for querying the Ribbon SBC:

SNMP  V2

Ribbon SBC SNMP V2 Field Descriptions

Fields

Setting

Version

V2

SNMP Community String

Community String as administered on the Ribbon SBC

SNMP V3

Ribbon SBC SNMP V3 Field Description

Fields

Setting

Version

V3

Username

SNMP V3 Username

Authentication Protocol

SHA (recommended)

Authentication Password

Password

Privacy Protocol

DES (recommended)

Privacy Password

Password

Test Access

Once all fields are populated Click on the Test Access button. This will test that VSM can connect to the Ribbon SBC using the settings you have entered: