Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Table of Contents

AXL Configuration

VSM use AXL API to collect data from CUCM, this can be achieved by creating user with AXL Capabilities within CUCM.

Enable AXL Service

Go to Cisco Unified Serviceability.

...

Make Sure AXL Web Service status is started, otherwise start it if it was deactivated or stopped.

AXL Web Service status

Create CUCM AXL User

Log in to Cisco Unified CM Administration to create AXL user.

...

Application User Information

Field

Value

User ID

This is the user that is going to be used by VSM to access the CUCM

Password

Enter the password for the new user.

Confirm Password

Type the same password again.


Application User Information

...

Signing to CUCM with the new AXL Account



CUCM SNMP Configuration

SNMP configuration is required as part of CUCM Monitoring, SNMP can be configured as V1 ,V2 or V3 based on the customer requirements.

Configure SNMP V1/V2

Navigate to Cisco Unified Serviceability>>SNMP>>V1/V2>>Community String

...

SNMP Community String Configuration

Field

Value

Community String Name

Enter the required Name

Hosted IP Address Information

Choose one of the following based on the client requirements

1-    Accept SNMP Packets from Any host.

2-    Accept SNMP Packets only from these Hosts

If you choose Accept SNMP Packets only form these hosts make sure to enter IP Address of VSM Probe server under Host IP Address


Access Privilege

Choose ReadNotifyOnly unless something else required from the customer

Apply to All Nodes

Check the check box to apply configuration to all servers within the cluster.


SNMP Community String Configuration

...

SNMP Notification Destination

Field

Value

Host IP Address

VSM Probe IP Address

Notification Type

Trap


SNMP Notification Destination

...

SNMP Notification Destination

Field

Value

Host IP Addresses

Add New is selected

Host IP Address

VSM Probe IP Address

Port Number

Default is 162, change it only if needed

SNMP Version

Choose either V1/V2C

Notification Type Information

Trap


SNMP Notification Destination Configuration – Add New Page

...

SNMP Notification Destination Configuration Status

CUCM SNMP V3 Configuration

Navigate to Cisco Unified Serviceability>>SNMP>>V3>>SNMP Destination Configuration and follow the same steps described earlier to add SNMP V2 Destination

...

SNMP V3 User configuration

Field

Value

User Name

Enter SNMP User Name

Authentication Required

Check the checkbox of Authentication

Password

Enter the Password

Protocol

Choose either MD5 or SHA

Privacy Required

Optional/check the checkbox if required

Password

Enter the password

Protocol

Choose the preferred Protocol (DES/AES128)

Accept SNMP Packets from Anyhost

Uncheck the checkbox

Accept SNMP  Packets only from these Hosts

Check the Check box

Host IP Address

Enter the IP Address of the VSM Probe and click Insert

Access Privileges

Choose ReadNotify Only

Apply to All Nodes

Check the checkbox


SNMP V3 User Configuration Page

...

SNMP V3 Notification Configuration



CUCM syslog configuration

Navigate to Cisco Unified CM Administration >> System >> Cisco Syslog Agent >>Remote Syslog Server Name

...

CUCM Syslog configuration



CDR Configuration

Navigate to Cisco Unified Serviceability>>Tools >> Control Centre – Feature Service >>Select Publisher from the drop down list and make sure All CDR services are up.

...

Billing Application Server Parameters

Field

Value

Host Name /IP Address

Enter Probe IP server

Username

Enter username details for SFTP

Password

Enter Password details for SFTP

Protocol

SFTP

Directory Path

\

Resend on Failure

Check the checkbox


Billing Application Server Parameters



CUCM Backup Configuration

The following is required to configure VSM as destination for backup files. These Backup files will be sent from the VSM Probe to the Virsae Cloud.

...

Enter the required details for the Backup Device

Backup Device Details

Field

Value

Backup Device Name

Enter Any name

Host name / IP Address

VSM Probe IP Address

Path name

\

User name

VSM SFTP server username

Password

VSM SFTP server password

Number of backups to store on Directory

Leave it to default – VSM Probe will send the backups to Virsae Cloud.


Configure backup scheduler by navigating to Backup >> Scheduler.

...

Make sure the schedule status is changed to Enabled.

Schedule Backup Enabled



Web Portal Configuration

Add CUCM

Login to the VSM web portal using your credentials and password.

...

Web Portal – Add CUCM Field Description

Field

Setting

Vendor

Cisco Systems

Product

Unified Communications Manager

Equipment Name

Friendly name for this CUCM

Username

Administrative Username

Password

Administrative Password

IP Address / Host Name

IP Address of server (Virtual in duplicated servers)

Site

Free text field, this information will be included in alarm notifications from the VSM Workflow.

Use Cisco APIs

Select if Using Cisco APIs for advanced options


Info
Site ID information in the ‘Site’ field will advise your NOC staff of the site where the Microsoft Server is physically located. This is particularly helpful when the customer has multiple sites.

...

CUCM SNMP V1/V2 Field Descriptions

Fields

Setting

Version

V1, V2

SNMP Community String

Community String as administered on the CUCM



SNMP V3

Web Portal – CUCM SNMP V3 Query

...

CUCM SNMP V3 Field Description

Fields

Setting

Version

V3

Username

SNMP V3 Username

Authentication Protocol

SHA (recommended)

Authentication Password

Password

Privacy Protocol

DES (recommended)

Privacy Password

Password


Once all fields are populated Click on the Test Access button. This will test that VSM can connect to the CUCM using the settings you have entered:

...