For your customer, select Service Desk > Equipment Locations. Right-click on the Equipment Location (Appliance) that will serve this particular Ribbon Edge SBC and select ‘Manage Equipment’
...
Select the Vendor 'Ribbon Communications' and Product 'SWe Lite, 1000, 2000 (Edge Series)'
Web Portal – Add Ribbon SBC Edge Field Description
Field | Setting |
Vendor | Ribbon Communication |
Product | 'SWe Lite, 1000, 2000 (Edge Series)' |
Equipment Name | Friendly name for this SBC |
API Username | API Username |
API Password | API Password |
IP Address / Host Name | IP Address of SBC |
Site | Free text field, this information will be included in alarm notifications from the VSM Workflow. |
SNMP
Complete the Equipment tab and then click on the ‘SNMP Query’ tab.
Click on the down arrow, and select the SNMP version you wish VSM to use for querying the Ribbon SBC:
SNMP V2
Ribbon SBC SNMP V2 Field Descriptions
Fields | Setting |
Version | V2 |
SNMP Community String | Community String as administered on the Ribbon SBC |
SNMP V3
Ribbon SBC SNMP V3 Field Description
Fields | Setting |
Version | V3 |
Username | SNMP V3 Username |
Authentication Protocol | SHA (recommended) |
Authentication Password | Password |
Privacy Protocol | DES (recommended) |
Privacy Password | Password |
Test Access
Once all fields are populated Click on the Test Access button. This will test that VSM can connect to the Ribbon SBC using the settings you have entered:
...