Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

For your customer, select Service Desk > Equipment Locations. Right-click on the Equipment Location (Appliance) that will serve this particular Ribbon Edge SBC and select ‘Manage Equipment’

...

Select the Vendor 'Ribbon Communications' and Product 'SWe Lite, 1000, 2000 (Edge Series)'

Image Modified



Web Portal – Add Ribbon SBC Edge Field Description

Field

Setting

Vendor

Ribbon Communication

Product

'SWe Lite, 1000, 2000 (Edge Series)'

Equipment Name

Friendly name for this SBC

API Username

API Username

API Password

API Password

IP Address / Host Name

IP Address of SBC

Site

Free text field, this information will be included in alarm notifications from the VSM Workflow.

SNMP

Complete the Equipment tab and then click on the ‘SNMP Query’ tab.

Click on the down arrow, and select the SNMP version you wish VSM to use for querying the Ribbon SBC:

SNMP  V2

Image Modified

Ribbon SBC SNMP V2 Field Descriptions

Fields

Setting

Version

V2

SNMP Community String

Community String as administered on the Ribbon SBC


SNMP V3

Ribbon SBC SNMP V3 Field Description

Fields

Setting

Version

V3

Username

SNMP V3 Username

Authentication Protocol

SHA (recommended)

Authentication Password

Password

Privacy Protocol

DES (recommended)

Privacy Password

Password

Test Access

Once all fields are populated Click on the Test Access button. This will test that VSM can connect to the Ribbon SBC using the settings you have entered:

...