Once You click Save it will show the list of roles assigned to the user.

Test new user account


Make sure you can sign in to CUCM with the newly created account by signing out and sign back in again with the your new account.

CUCM SNMP Configuration

...

Browse to the CUCM then select '"Cisco Unified Serviceability' " from the navigation menu.

...

Navigate to SNMP>V1/V2>Community String

SNMP V1/V2


SNMP Community String Configuration


From the drop-down List Choose the server you want to configure SNMP and click find>>Add new if none was configured.

SNMP  need SNMP needs to be configured on all the servers in the CUCM Cluster.

SNMP Community String Configuration


Fill in the SNMP Community String Page with the following values.

...

Field

Value

Community String Name

Enter the required Name

Hosted IP Address Information

Choose one of the following based on the client requirements

1-    Accept SNMP Packets from Any host.

2-    Accept SNMP Packets only from these Hosts

If you choose Accept SNMP Packets only form these hosts make sure to enter IP Address of VSM Probe server under Host IP Address


Access Privilege

Choose ReadNotifyOnly unless something else required from the customer

Apply to All Nodes

Check the check box to apply configuration to all servers within the cluster.

SNMP Community String Configuration


SNMP Sample Configuration


When you click save warning will display notifying of restarting SNMP Master Agent Service for the change to take effect, click ok to restart the service.

SNMP Service Restart


Once completed the following message display with the status of the restart.

SNMP Service Restart Status


Configure CUCM to send SNMP Traps by navigating to SNMP>>V1/V2>>Notification Destination

...

Field

Value

Host IP Address

VSM Probe IP Address

Notification Type

Trap

SNMP Notification Destination


Choose server >>Find>>Click Add New

SNMP Notification Destination Server Selection


The following page appearappears, from the drop-down list choose "Add newNew".

SNMP Notification Destination Configuration


SNMP Notification Destination Configuration Drop Down List


Enter the Values in the page as per the following table.

SNMP Notification Destination

Field

Value

Host IP Addresses

Add New is selected

Host IP Address

VSM Probe IP Address

Port Number

Default is 162, change it only if needed

SNMP Version

Choose either V1/V2C

Notification Type Information

Trap


SNMP Notification Destination Configuration – Add New Page


SNMP Notification Destination Configuration Sample Configuration


Once you choose Notification Type Community String Information will display.

Choose the community String created earlier and check apply to All Nodes.

SNMP Notification Destination Configuration – Apply To All Nodes


Click ok for the pop to restart the SNMP Master Agent Service as before unless client want to do it later.

Notification Destination Service Restart.


Once restart is completed SNMP Notification Destination Configuration will show the new Destination IP Address.

SNMP Notification Destination Configuration Status

CUCM SNMP V3 Configuration

Navigate to SNMP>V3>UserSNMP> V3> User

SNMP V3 User Configuration 


Select Server from the drop-down list and click find.

SNMP V3 User Configuration


Click Add New to create SNMP User

...

Field

Value

User Name

Enter SNMP User Name

Authentication Required

Check the checkbox of Authentication

Password

Enter the Password

Protocol

Choose either MD5 or SHA

Privacy Required

Optional/check the checkbox if required

Password

Enter the password

Protocol

Choose the preferred Protocol (DES/AES128)

Accept SNMP Packets from Anyhost

Uncheck the checkbox

Accept SNMP  Packets only from these Hosts

Check the Check box

Host IP Address

Enter the IP Address of the VSM Probe and click Insert

Access Privileges

Choose ReadNotify Only

Apply to All Nodes

Check the checkbox


SNMP V3 User Configuration Page


SNMP V3 User Configuration Example


Click ok to the pop up to restart SNMP master agent for configuration to take effect

SNMP Master Agent Pop UP to restart the service


Once restart is completed SNMP user configuration will be displayed with the new user configured.

SNMP V3 User Configuration

 

  Navigate to Snmp >> V3 >> Notification Destination 

SNMP V3 Notification Destination


Choose server >>Find>>Click Add New

SNMP Notification Destination Server Selection


The following page appear, from the drop down list choose Add new.

SNMP Notification Destination Configuration


SNMP Notification Destination Configuration Drop Down List


Enter the Values in the page as per following

...

Field

Value

Host IP Addresses

Add New is selected

Host IP Address

VSM Probe IP Address

Port Number

Default is 162, change it only if needed

SNMP Version

Choose either V1/V2C

Notification Type Information

Trap

Security Level

Choose based on the security Level configured in the the user

User InformationCheck the check box next to user created
Apply to All NodesCheck the check box next to Apply to All Nodes

Click Insert.



SNMP Notification Destination Configuration Sample Configuration


Click ok to the pop up to restart SNMP master agent for configuration to take effect

SNMP Master Agent Pop UP to restart the service

CUCM Syslog configuration

...

Syslog Severity for Remote Syslog messages >> Choose based on the requirements


CUCM Syslog configuration

CDR Configuration

Navigate to Cisco Unified Serviceability

...

Start the services if it was deactivated or stopped.


Control Centre – Feature Service CDR Services


Navigate to Cisco Unified Serviceability >> Tools >> Control Centre – Network Services >> Select Publisher from the drop down list and make sure all CDR services are up.

Control Centre – Network Services Publisher CDR Services


Navigate to Cisco Unified Serviceability >> Tools >> Control Centre – Network Services >> Select Subscriber from the drop down list and make sure CDR Agent service is running.

Repeat the above step for all subscribers in the Cluster.

Control Centre  - Network Services Subscriber CDR Service


Navigate to Cisco Unified CM Administration >> System >> Service Parameter >> Call Manager Service. Set the CDR Enabled Flag to True. This has to be done for all the nodes in the server.

CUCM Service Parameters Configuration


Set up CDR Enabled Flag and CDR Log Calls with Duration to True


Repeat above step for all CUCM Servers in the cluster.

navigate to System >> Service Parameter >> Call Manager Service>> Clusterwide Parameters >> Call Diagnostics Enabled parameter to Enabled Only When CDR Enabled Flag is True

Setup Call Diagnostics – Enable CMR


Now add SFTP server/Billing Server where the files are to be sent. Navigate to Cisco Unified Serviceability > Tools > CDR Management and add new billing server.

CDR Management Page


Billing Application Server Parameters

Field

Value

Host Name /IP Address

Enter Probe IP server

Username

Enter username details for SFTP

Password

Enter Password details for SFTP

Protocol

SFTP

Directory Path

\

Resend on Failure

Check the checkbox


Billing Application Server Parameters

Anchor
CUCM Backup Configuration
CUCM Backup Configuration
CUCM Backup Configuration

...

Navigate to  Backup >> Backup Device >> Add New

Disaster Recovery Page


Enter the required details for the Backup Device

...

Configure a schedule backup based on your scenario, recommended Daily backup after hours.

Backup Schedule


Click on Save and notice the warning as shown in the image. Click on OK in order to move forward.

Backup Warning


Once the Backup Schedule is created, click on Enable Schedule

Enable Schedule


Make sure the schedule status is changed to Enabled.

Schedule Backup Enabled

Web Portal Configuration

Add CUCM

...