Info |
---|
This |
...
section makes frequent use of data contained in |
...
...
. All relevant sections of the Technical |
...
Requirements Data collection should be completed or known before commencing with the steps in this |
...
section. |
...
Table of Contents |
---|
Web Portal Setup
Avaya Ethernet Switches are setup in VSM to enable Access Concentrator, to add a friendly name and default site for alarming purposes, as well as facilitating an offsite backup capability.
...
A form will open which you can populate with the equipment details as per table 1.
Select the Vendor ‘Avaya’ and Product ‘Ethernet Switch’.
Web Portal – Add Equipment
If you are adding more than one piece of the same equipment type check the ‘Add another’ box at the bottom of the form and the bulk of the configuration will be carried over for the next item.
...
Info |
---|
Site ID information in the ‘Site’ field will advise your NOC staff of the site where the Avaya Ethernet Switch is physically located. This is particularly helpful when the customer has multiple sites. |
Web Portal - AES Configure Equipment
Complete the Equipment tab and then click on the ‘SNMP Query’ tab.
Click on the down arrow, and select the SNMP version you wish VSM to use for querying the AES:
SNMP V1 or V2
Web Portal – AES SNMP V1/V2 QueryAES SNMP V1/V2 Field Descriptions
Field | Setting |
Version | V1, V2 |
SNMP Community String | Community String that is allowed Read access to the device. |
SNMP V3
Web Portal – AES SNMP V3 QueryAES SNMP V3 Field Description
Field | Setting |
Version | V3 |
Username | SNMP V3 Username |
Authentication Protocol | SHA (recommended) |
Authentication Password | Password |
Privacy Protocol | DES (recommended) |
Privacy Password | Password |
...
Info |
---|
The SSH test ensures the VSM probe collector can connect to, and login using the account configured. |
...