Click on Data Backup/Restore > Schedule Backup > Add:

FieldsSetting

Method

sftp (Secure File Transfer Protocol)

User Name

Must match the SFTP Backup settings in the Web Portal Equipment Location

Password

Must match the SFTP Backup settings in the Web Portal Equipment Location

Hostname

VSM Probe IP Address (V4)

Directory

/

...

FieldSetting

Local Node

ProcR or C-Lan

Local Port

0

Remote Node

virsae

Remote Port

9000

Reliable ProtocolN
Packet Response Timer30
Session Connect Message Cntr3
SPDU Cntr3
Connectivity Timer60

Submit the form.


ACM System-parameters CDR

Use the command 'Change System-Parameters CDR' – using either the primary, if available, or the secondary, if the primary is in use.

Enter the output type as 'Unformatted' and names the output Endpoint CDR1 or CDR2:  
Image RemovedImage Added

FieldsSetting

Primary/Secondary Output Format (use whichever is spare)

Unformatted

Primary/Secondary Output Format (use whichever is spare)

CDR1 or 2

Submit the form.

Configure RTCP for VQM

The following changes are required to define the VSM Probe as the destination for RTCP (Voice Quality) traffic from the UC environment:
Image Removed
ACM System-parameters IP-Options
ACM System-parameters IP-Options Field DescriptionImage Added

Fields

Field

Setting

Default Server IP Address

VSM Probe IP Address (V4)

Default Server Port

5005 – see note *See Note

Default RTCP Report Period (secs)

5


Info

Note: A single Equipment Location can support multiple RTCP Receivers.

Each individual ACM and its adjuncts should report to a separate discrete RTCP Receiver using a unique port for each.

Submit the form. Optional: Change 46xxsettings.txt file. The following lines can be added to the 46xxsettings file:


SIP Endpoints RTCP

The following settings in the 46xx Settings file are mandatory if you have SIP endpoints and you wish to receive VQM for their calls.

Code Block
languagebash
SET RTCPCONT 	
SET RTCPMON {
Wiki Markup
SET RTCPMON \[VSM Probe IP Address (V4)\]}
SET RTCPMONPORT 5005SET5005
SET RTCPMONPERIOD 5

...


Warning

After these entries have been put into the settings file you will need to restart SIP endpoints for them to take effect.

Avaya Agent For Desktop RTCP

If you are using Avaya Agent for desktop, the RTCP settings need to be set on each client using the following steps:


In the system tray, right-click the Avaya Agent for Desktop icon and select Configuration.

The system displays the Avaya Agent for Desktop Configuration window.

  1. In the Avaya Agent for Desktop Configuration window, select the Advanced tab.
  2. In the RTCP Monitoring Server Settings section, perform the following actions:
    1. In the Address field, type the IP address of the VSM probe.
    2. In the Port field, type the port number of the VSM RTCP receiver.
    3. In the Period field, enter ‘5 seconds’.
  3. Click Save.


Warning

ADDING: Avaya OneX Agent/Communicator


Web Portal Configuration

Add ACM

Login to the VSM web portal using your credentials and password.

For the particular your customer, select Service Desk > Equipment Locations.

Right-click on the Equipment Location (Appliance) that will serve this particular ACM:UC Server and select 'Manager Equipment'.


At the bottom of the 'Manage Equipment' page click on the 'Add Equipment' button.

A form will open which you can populate with the equipment details using this table.
Image Removed



Web Portal - All Equipment Locations
Click on Manage Equipment.

Web Portal – Manage Equipment
Click on Add Equipment.
A form will open which you can populate with the equipment details as per table 12.
If you are adding more than one piece of the same equipment type check the 'Add another' box at the bottom of the form and the bulk of the configuratuon will be carried over for the next item.

Web Portal – Add Equipment


Web Portal - ACM Configure Equipment
Web Portal – Add ACM Field Description

...