Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Cisco CUBEs use IOS-XE  (Linux based OS). IOS-XE Process separation allows use of multiple HW hardware types or multi-core.

CUBE Architecture includes a Data data plane and Control Plane.VSM control plane. VSM monitors the Control Plane control plane processor and memory, and this is displayed in the dashlet as Processor CPU & Memory.  LikewiseSimilarly, the Data Plane data plane is shown as Platform CPU & Memory.  

...

Alerts will highlight when any of interfaces is down.

Environment

VSM monitors the  status of the CUBE environments this includes (Voltage &  Temperature  & Power Supply and Fan) , it display CUBE environmental factors including voltage, temperature, power supply and fans. The dashlet displays the total number of monitored environment environmental components summarized based on the their health status.

Alerts will be highlighted as red and amber based on the potential impact:

Red - If  If any of Environmental State is  either (Critical , Shutdown or Not Functioning)environmental states are critical, shutdown or not functioning. 

Amber  - If any of Environmental State is Warning.environmental states are warning.

Drilling down into the environment tab Environment Drill Down will show the following  following details of  of each components:

Environment Voltage State

  • State -  Display Displays the state of associated instance .
  • Value - Display the current value of the associated instance 
  • Description  - Description of associated instance
  • Low Threshold - The lowest voltage  voltage that the associated instance of the object may obtain before an emergency shutdown of the managed device is initiated
  • High Threshold -  The highest voltage that the associated instance of the object  object may obtain before an emergency shutdown of the managed device is initiated.
  • Last Shutdown -  The voltage value of the associated instance of the object at the time an emergency shutdown of the managed device was last initiated

...

  • State -  State of associated instance
  • Value -  Current value of associated instance
  • Description  - Description of associated instance
  • Threshold -    The highest Temperature  temperature  that the associated instance  instance may obtain before an emergency shutdown of the managed device is initiated.
  • Last Shutdown -  The Temperature temperature value of the associated instance of the object at the time an emergency shutdown of the managed device was last initiated

...

  • State -  State of associated Power Supplypower supply
  • Description  - Description of associated Power Supplypower supply
  • Source  -  The Power power supply source

Environment Fan State

  • State -  State of associated Fanfan
  • Description  - Description of associated Fanfan

Dial-Peer Summary

Dial Peers identify call source and destination endpoints and define the characteristics that are applied to each call leg in a a call connection.

...

Alerts will be highlighted as red and amber based on the potential impact:

Red - If Admin State & Operate State are  both down, or the Keep Alive is in a busy out of service state.

...

  • 1xx Response
  • 2xx Response
  • 3xx Response
  • 4xx Response – totals here indicate a problem
  • 5xx Response - totals here indicate a problemResponse 
  • 6xx Response - totals here indicate a problemResponse 

Call Legs

VSM monitors  the number of active call legs per protocol:

...