Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Select the Session Manager you wish to configure from the 'Session Manager Instances' list, then click the 'Read' button at the top of the page

Configure using the table below, then click the 'Commit' button at the top of the page. Repeat this for any other Session Managers you wish to administer for SIP Trace output.

SM SIP Tracer Field Description

Anchor
SIPTracer6-7
SIPTracer6-7

Field

Setting

Send Trace Method

Syslog

Tracer Enabled

Checked

Trace All Messages

Checked

From Network to Security ModuleUnchecked or Grey
From Server to Security ModuleUnchecked or Grey
Trace Dropped MessagesUnchecked or Grey
Send Trace to a Remote ServerChecked

Remote Server FQDN or IP Address

IP Address of VSM collector

Stunnel PortGrey (Not Required)
From Security Module to NetworkUnchecked or Grey
From Security Module to ServerUnchecked or Grey
Max Dropped Message Count1 or higher
Send Trace MethodSyslog (Unsecure UDP)


Info

‘Max Dropped Message Count’ cannot be zero. Increase this to 1 at a minimum. 

...

SM SIP Tracer Field Description

Syslog
FieldSetting

Remote Server FQDN or IP Address

IP Address of VSM collector

Tracer Enabled

Checked

Trace All Messages

Checked

From Network to Security ModuleUnchecked or Grey
From Security Module to NetworkUnchecked or Grey
From Server to Security ModuleUnchecked or Grey
From Security Module to ServerUnchecked or Grey
Trace Dropped MessagesUnchecked or Grey
Max Dropped Message Count1 or higher

Send Trace Method


Info

‘Max Dropped Message Count’ cannot be zero. Increase this to 1 at a minimum. 

...