Fill in the required fields as below 

FieldValueMandatory / optional
Group NameSpecifies the name of RADIUS class to which a SBC Edge access level is assigned ,Class Name is case sensitive and must match the RADIUS class exactlyMandatory
Access LevelSelect REST from the drop downMandatory

Additional Details can be found here

Ribbon SBC Edge SNMP Configuration

SNMP configuration is required as part of Ribbon SBC Edge Monitoring . SNMP can be configured as  V2, or V3 based on customer requirements.

Browse to SBC then Navigate to SNMP/Alarms > SNMP Management Address

Image Added

Click the (plus) icon to to add New SNMP Manager Address


SNMP Version 2 Option

Image Added

Fill in the required fields as below

FieldValueMandatory / Optional
Manager AddressEnter IP Address of VSM ProbeMandatory
SNMP VersionSelect Version 2 From the drop downMandatory
CommunityEnter the Community StringMandatory
Community TypeRead-OnlyMandatory
Trap EnabledTrueMandatory


SNMP Version 3 Option

Image Added


Fill in the Fields as below:

FieldValueMandatory / Optional
Manager AddressEnter IP Address of VSM ProbeMandatory
SNMP VersionSelect Version 3 from the drop downMandatory
Community TypeRead-onlyMandatory
USM User NameEnter SNMP UsernameMandatory
Auth ProtocolSelect any of the options (None , MD5 or SHA 1Mandatory
Auth PasswordEnter Auth Password - applicable only if selected Auth Protocol is MD5 or SHA1Mandatory
Confirm Auth PasswordRepeat Auth password entered above to confirmMandatory
Priv Protocol

AES 128 must be selected if Auth Protocol is set to anything other than None,

Otherwise None can be selected

Mandatory
Priv Password

Enter Privacy Password.

Hidden when Priv Protocol is set to None

Mandatory
Confirm Priv PasswordRepeat password entered above to confirmMandatory
Trap EnabledSelect True from Drop DownMandatory


Additional details can be found here