Fill in the required fields as below
Field | Value | Mandatory / optional |
---|---|---|
Group Name | Specifies the name of RADIUS class to which a SBC Edge access level is assigned ,Class Name is case sensitive and must match the RADIUS class exactly | Mandatory |
Access Level | Select REST from the drop down | Mandatory |
Additional Details can be found here
Ribbon SBC Edge SNMP Configuration
SNMP configuration is required as part of Ribbon SBC Edge Monitoring . SNMP can be configured as V2, or V3 based on customer requirements.
Browse to SBC then Navigate to SNMP/Alarms > SNMP Management Address
Click the icon to to add New SNMP Manager Address
SNMP Version 2 Option
Fill in the required fields as below
Field | Value | Mandatory / Optional |
---|---|---|
Manager Address | Enter IP Address of VSM Probe | Mandatory |
SNMP Version | Select Version 2 From the drop down | Mandatory |
Community | Enter the Community String | Mandatory |
Community Type | Read-Only | Mandatory |
Trap Enabled | True | Mandatory |
SNMP Version 3 Option
Fill in the Fields as below:
Field | Value | Mandatory / Optional |
---|---|---|
Manager Address | Enter IP Address of VSM Probe | Mandatory |
SNMP Version | Select Version 3 from the drop down | Mandatory |
Community Type | Read-only | Mandatory |
USM User Name | Enter SNMP Username | Mandatory |
Auth Protocol | Select any of the options (None , MD5 or SHA 1 | Mandatory |
Auth Password | Enter Auth Password - applicable only if selected Auth Protocol is MD5 or SHA1 | Mandatory |
Confirm Auth Password | Repeat Auth password entered above to confirm | Mandatory |
Priv Protocol | AES 128 must be selected if Auth Protocol is set to anything other than None, Otherwise None can be selected | Mandatory |
Priv Password | Enter Privacy Password. Hidden when Priv Protocol is set to None | Mandatory |
Confirm Priv Password | Repeat password entered above to confirm | Mandatory |
Trap Enabled | Select True from Drop Down | Mandatory |
Additional details can be found here