Replace the variables as per the table below:
Field | Description |
---|---|
IPAddress | The IP Address of the VSM Collector |
Username | The SNMPV3 username administered in VSM |
authpwd | The Authorisation Password for the SNMPV3 user administered in VSM |
auth | The Authorisation type for the SNMPV3 User: MD5 or SHA |
privpwd | The privacy password for the SNMPV3 user administered in VSM |
priv | The Privacy type for the SNMPV3 user: DES, AES128, AES192, AES256 |
engID | SNMP Engine ID - This is the code '0x80001ae903' followed by the AAM/IX server MAC address with hyphens removed e.g. if the MAC address is 00-FF-39-B4-A8-38, then the engine ID will be 0x80001ae90300FF39B4A838 |
For e.g. To set this for a VSM collector on 192168.10.1, with an SNMPV3 user account virsae with the password virsae123 using Authorisation type SHA and Privacy type DES and the AAM server MAC address is 00-FF-39-B4-A8-38 use the following script:
...
The ucsnmpservice service must be restarted after executing the command line.
To issue a test trap from AAM/IX use the following command at the command prompt:
Code Block |
---|
UCSNMPConfig.exe trap test |