Introduction

It is essential that certain prerequisites are met before you use this document to configure Protocol Validation . Refer to the Implementation Guide for the correct process flow.

By following the flow chart you will have all the information required, and the work will be completed in the correct order so that work won’t have to be repeated and tests run at the time will be relevant.

Prerequisite

This document makes frequent use of data contained in the Technical Requirements document.

All relevant sections of the Technical Requirements document must be completed before commencing with the steps in this document.

Configuration

Protocol Validation is setup in VSM to provide assurance that an application is operational.

...

1.To add a Protocol Validation test to VSM, select the customer you wish to add the test for, then navigate to Service Desk> Equipment Locations:

Image Modified


2. Next, right-click on the equipment Equipment Location you want to add a Protocol Validation for. Go down to Network> Protocol Validation Configuration:

Image Modified


3. To create a new Protocol Validation, click "Add Protocol Validation":

Image Modified


4. Populate the form with details of the Protocol Validation test you are adding. Refer to the table below.

Image Modified


Configuration Table:
Anchor
Config_table
Config_table

FieldDescriptionRestrictions
TypeThis is the protocol to be validated.
Details
Alarm Name (Auto-filled)

If the protocol validation fails, e.g. the service becomes unavailable, this will be the name of the alarm raised.


NameA description of the protocol validation, which will also be shown in the alarm details, and on the protocol validation availability page.
SiteFree text used to identify the site.  Can be blank
Criteria
Address

The target address, can be a DNS name, or IP Address. 

For example: www.mywebsite.com:8080/firstpage/secondpage

For SIP OPTIONS, SIP URI is also supported
Port

The port the service runs on. If left blank, the default port for that protocol will be used.

Default ports:

80 = HTTP

443 = HTTPS

25 = SMTP

22 = SSH

23 = Telnet

Undefined = Raw TCP Socket


Poll Frequency (mins)

The frequency of the protocol validation is tested, in minutes. Valid values are 1 – 1440.

We recommend setting this to 2 minutes, for immediate results on failure.


Validation

Specifies whether the address is accessed internally within the intranet, or externally via a public-facing IP Address. 

For public websites, this should be set to External.

Note: It is not possible to test an external validation.


Additional Configuration options
Ignore Certificate Errors

For HTTPS a security certificate needs to be installed on the target equipment.   Sometimes, this cannot be verified, resulting in browsers displaying a warning instead of loading the page. 


If this is the expected response for the site, click 'Ignore Certificate Errors'

HTTPS only
Override Failed Responses

To customize the default behaviour and classify failure responses as a success, list the specific response codes as a comma separated input in the field below.

For example, to ignore authentication errors, add: 401, 407.
SIP OPTIONS only
SIP Proxy AddressThis is the SIP Proxy address and is an IP Address. SIP Proxy, sometimes also called SIP Server, or SIP Proxy server facilitates the communication between two SIP addresses. It is the go-between two SIP devices allowing them to set up communication, and drops out once established allowing point to point communication.SIP OPTIONS only
SIP Proxy PortThis is the port used by the SIP proxy. It is typically 5060 for non-encrypted signalling traffic, or 5061 for encrypted traffic, encrypted with Transport Layer Security (TLS). If left blank, the default 5060 will be used.SIP OPTIONS only
SIP Protocol

This is the protocol used by the target SIP client. SIP clients typically use TCP or UDP for encrypted SIP traffic to servers and other endpoints.  If SIP Proxy Port is 5061, specify TLS.

SIP OPTIONS only
UsernameThe username to log on to the target address with.SSH, Telnet and SIP Options
PasswordThe password to log on to the target address withSSH, Telnet and SIP Options


Test Configuration

To check that the Protocol Validation is working press the “Test” button when all mandatory fields have been entered.

Image Modified


Once the Protocol Validation test is working, click “Add” and the Protocol Validation Test will be saved in VSM. If not, troubleshoot by checking that all fields have been entered correctly.

Results

Once Configured protocol validation results typically start working after a few minutes.  The following colour bars are used

  • Green: A successful connection with successful Response Code
  • Red: A failed response code was returned, either because the target was unreachable, or the service running on that protocol was responding with an error. This will raise an alarm.
  • Black: Internal error. Contact your system administrator.


Protocol Validation Availability

View full results on the Protocol Validation Availability page

...