AXL Configuration

VSM use AXL API to collect data from CUCM, this can be achieved by creating user with AXL Capabilities within CUCM.

Enable AXL Service

Go to Cisco Unified Serviceability.

...

Make Sure AXL Web Service status is started, otherwise start it if it was deactivated or stopped.

AXL Web Service status

Create CUCM AXL User

Log in to Cisco Unified CM Administration to create AXL user.

...

Field

Value

User ID

This is the user that is going to be used by VSM to access the CUCM

Password

Enter the password for the new user.

Confirm Password

Type the same password again.


Image Added

Application User Information


Image Added

Figure 16 – VSM Application User


Under Permission Information in the new created Application User click on Add to Access Control Group.

Image Added

Figure 17 – Application User Configuration – Permission Information


In the search bar type the name of previously created Access Control Group.

Image Added

Figure 18 – Find and List Access Control Groups


Enter the name of previously created Access Control Group >>Click Find>>Check the checkbox next to Access control Group and Click Add Selected.

Image Added

Figure 19 – Assign AXL Access Control Group  to the VSM AXL User


Click Save under Application User Configuration.

Image Added

Figure 20 – Application user with the new Access Groups Assigned


Once You click Save it will show the list of roles assigned to the user.

Image Added

Figure 21 – Application User Final Status.


Make sure you can sign in to CUCM with the newly created account by signing out and sign back in again with the your new account.

Image Added

Figure 22 – Signing to CUCM with the new AXL Account

...



CUCM SNMP Configuration

SNMP configuration is required as part of CUCM Monitoring, SNMP can be configured as V1 ,V2 or V3 based on the customer requirements.

...

Configure SNMP V1/V2

Navigate to Cisco Unified Serviceability>>SNMP>>V1/V2>>Community String


Image Added

Figure 23 – Cisco Unified Serviceability Navigation


Image Added

Figure 24 – SNMP V1/V2


Image Added

Figure 25 – SNMP Community String Configuration


From the drop down List Choose the server you want to configure SNMP and click find>>Add new if none was configured.

SNMP  need to be configured on all the servers in CUCM Cluster.

Image Added

Figure 26 – SNMP Community String Configuration


Fill in the SNMP Community String Page with the following values.

Table 2 – SNMP Community String Configuration

Field

Value

Community String Name

Enter the required Name

Hosted IP Address Information

Choose one of the following based on the client requirements

1-    Accept SNMP Packets from Any host.

2-    Accept SNMP Packets only from these Hosts

If you choose Accept SNMP Packets only form these hosts make sure to enter IP Address of VSM Probe server under Host IP Address


Access Privilege

Choose ReadNotifyOnly unless something else required from the customer

Apply to All Nodes

Check the check box to apply configuration to all servers within the cluster.


Image Added

Figure 27 – SNMP Community String Configuration


Image Added

Figure 28 – SNMP Sample Configuration


When you click save warning will display notifying of restarting SNMP Master Agent Service for the change to take effect, click ok to restart the service.

Image Added

Figure 29 – SNMP Service Restart


Once completed the following message display with the status of the restart.

Image Added

Figure 30 – SNMP Service Restart Status


Configure CUCM to send SNMP Traps by navigating to SNMP>>V1/V2>>Notification Destination

Table 3 – SNMP Notification Destination

Field

Value

Host IP Address

VSM Probe IP Address

Notification Type

Trap


Image Added

Figure 31 – SNMP Notification Destination


Choose server >>Find>>Click Add New

Image Added

Figure 32 – SNMP Notification Destination Server Selection


The following page appear, from the drop down list choose Add new.

Image Added

Figure 33 – SNMP Notification Destination Configuration


Image Added

Figure 34 – SNMP Notification Destination Configuration Drop Down List


Enter the Values in the page as per following

Table 4 – SNMP Notification Destination

Field

Value

Host IP Addresses

Add New is selected

Host IP Address

VSM Probe IP Address

Port Number

Default is 162, change it only if needed

SNMP Version

Choose either V1/V2C

Notification Type Information

Trap


Image Added

Figure 35 – SNMP Notification Destination Configuration – Add New Page


Image Added

Figure 36 – SNMP Notification Destination Configuration Sample Configuration


Once you choose

...

Notification Type Community String Information will

...

display.

Choose the community String created earlier and check apply to All Nodes.

Image Added

Figure 37 – SNMP Notification Destination Configuration – Apply To All Nodes


Click ok for the pop to restart the SNMP Master Agent Service as before unless client want to do it later.

Image Added

Figure 38 – Notification Destination Service Restart.


Once restart is completed SNMP Notification Destination Configuration will show the new Destination IP Address.

Image Added

Figure 39 – SNMP Notification Destination Configuration Status

...

CUCM SNMP V3 Configuration

Navigate to Cisco Unified Serviceability>>SNMP>>V3>>SNMP Destination Configuration and follow the same steps described earlier to add SNMP V2 Destination


Image AddedImage Added

Figure 40 – SNMP V3 SNMP Destination Configuration


Select Server from the drop down list and click find.

Image Added

Figure 41 – SNMP V3 User Configuration


Click Add New to create SNMP User

 

Table 5 – SNMP V3 User configuration

Field

Value

User Name

Enter SNMP User Name

Authentication Required

Check the checkbox of Authentication

Password

Enter the Password

Protocol

Choose either MD5 or SHA

Privacy Required

Optional/check the checkbox if required

Password

Enter the password

Protocol

Choose the preferred Protocol (DES/AES128)

Accept SNMP Packets from Anyhost

Uncheck the checkbox

Accept SNMP  Packets only from these Hosts

Check the Check box

Host IP Address

Enter the IP Address of the VSM Probe and click Insert

Access Privileges

Choose ReadNotify Only

Apply to All Nodes

Check the checkbox


Image Added

Figure 42 – SNMP V3 User Configuration Page


Image Added

Figure 43 – SNMP V3 User Configuration Example


Click ok to the pop up to restart SNMP master agent for configuration to take effect

Image Added

Figure 44 – SNMP Master Agent Pop UP to restart the service


Once restart is completed SNMP user configuration will be displayed with the new user configured.

Image Added

Figure 45 – SNMP V3 User Configuration

 

 Follow the same steps described in configuring SNMP Notification Configuration on SNMP V2 section.

Image Added

Figure 46 – SNMP V3 Notification Configuration

...



CUCM syslog configuration

Navigate to Cisco Unified CM Administration >> System >> Cisco Syslog Agent >>Remote Syslog Server Name

Enter the IP Address of VSM Probe as one of Remote Syslog Severs.

Syslog Severity for Remote Syslog messages >> Choose based on the requirements

Image Added

Figure 47 – CUCM Syslog configuration

...



CDR Configuration

Navigate to Cisco Unified Serviceability>>Tools >> Control Centre – Feature Service >>Select Publisher from the drop down list and make sure All CDR services are up.

Start the services if it was deactivated or stopped.


Image Added

Figure 48 – Control Centre – Feature Service CDR Services


Navigate to Cisco Unified Serviceability >> Tools >> Control Centre – Network Services >> Select Publisher from the drop down list and make sure all CDR services are up.

Image Added

Figure 49 – Control Centre – Network Services Publisher CDR Services


Navigate to Cisco Unified Serviceability >> Tools >> Control Centre – Network Services >> Select Subscriber from the drop down list and make sure CDR Agent service is running.

Repeat the above step for all subscribers in the Cluster.

Image Added

Figure 50 – Control Centre  - Network Services Subscriber CDR Service


Navigate to Cisco Unified CM Administration >> System >> Service Parameter >> Call Manager Service. Set the CDR Enabled Flag to True. This has to be done for all the nodes in the server.

Image Added

Figure 51 – CUCM Service Parameters Configuration


Image Added

Figure 52 – Set up CDR Enabled Flag and CDR Log Calls with Duration to True


Repeat above step for all CUCM Servers in the cluster.

navigate to System >> Service Parameter >> Call Manager Service>> Clusterwide Parameters >> Call Diagnostics Enabled parameter to Enabled Only When CDR Enabled Flag is True

     Image Added

Figure 53 – Setup Call Diagnostics – Enable CMR


Now add SFTP server/Billing Server where the files are to be sent. Navigate to Cisco Unified Serviceability > Tools > CDR Management and add new billing server.

Image Added

Figure 54 – CDR Management Page


Table 6 – Billing Application Server Parameters

Field

Value

Host Name /IP Address

Enter Probe IP server

Username

Enter username details for SFTP

Password

Enter Password details for SFTP

Protocol

SFTP

Directory Path

\

Resend on Failure

Check the checkbox


Image Added

Figure 55 – Billing Application Server Parameters

...



CUCM Backup Configuration

The following is required to configure VSM as destination for backup files. These Backup files will be sent from the VSM Probe to the Virsae Cloud.

Navigate Disaster Recovery System >> Backup >> Backup Device >> Add New

Image Added

Figure 56 – Disaster Recovery Page


Enter the required details for the Backup Device

Table 7 – Backup Device Details

Field

Value

Backup Device Name

Enter Any name

Host name / IP Address

VSM Probe IP Address

Path name

\

User name

VSM SFTP server username

Password

VSM SFTP server password

Number of backups to store on Directory

Leave it to default – VSM Probe will send the backups to Virsae Cloud.


Configure backup scheduler by navigating to Backup >> Scheduler.

Define Scheduler Name. Select the Device name (the device created earlier) and check the features you want to backup, ideally check all the options.

If using CUCM prior to Version 12.0, the features are CDR_CAR, UCM and PLM. If using CUCM Version 12.0 and later, the features are CDR_CAR, UCM and IM_AND_PRESENCE.

Image Added

Figure 57 –CUCM CUCM Backup features prior to Version 12.0


Image Added

Figure 58 - CUCM Backup features for Version 12.0 and later


Configure a schedule backup based on your scenario, recommended Daily backup after hours.

Image Added

Figure 59 – Backup Schedule


Click on Save and notice the warning as shown in the image. Click on OK in order to move forward.

Image Added

Figure 60 – Backup Warning


Once the Backup Schedule is created, click on Enable Schedule

Image Added

Figure 61 – Enable Schedule


Make sure the schedule status is changed to Enabled.

Image Added

Figure 62 – Schedule Backup Enabled

...



Web Portal Configuration

...

Add CUCM

Login to the VSM web portal using your credentials and password.

...

Select the Vendor ‘Cisco Systems’ and Product ‘Unified Communications Manager’.

Image Added

Figure 63 – Web Portal – Add Equipment


If you are adding more than one piece of the same equipment type check the ‘Add another’ box at the bottom of the form and the bulk of the configuration will be carried over for the next item.

 

Table 8 - Web Portal – Add CUCM Field Description

Field

Setting

Vendor

Cisco Systems

Product

Unified Communications Manager

Equipment Name

Friendly name for this CUCM

Username

Administrative Username

Password

Administrative Password

IP Address / Host Name

IP Address of server (Virtual in duplicated servers)

Site

Free text field, this information will be included in alarm notifications from the VSM Workflow.

Use Cisco APIs

Select if Using Cisco APIs for advanced options


Info
Site ID information in the ‘Site’ field will advise your NOC staff of the site where the Microsoft Server is physically located. This is particularly helpful when the customer has multiple sites.



Image Added

Figure 64 - Web Portal - CUCM Configure Equipment

 

Complete the Equipment tab and then click on the ‘SNMP Query’ tab.

Click on the down arrow, and select the SNMP version you wish VSM to use for querying the CUCM:


SNMP V1 or V2

Image Added

Figure 65 - Web Portal – CUCM SNMP V1/V2 Query


Table 9 - CUCM SNMP V1/V2 Field Descriptions

Fields

Setting

Version

V1, V2

SNMP Community String

Community String as administered on the CUCM



SNMP V3


Image Added

Figure 66 - Web Portal – CUCM SNMP V3 Query


Table 10 - CUCM SNMP V3 Field Description

Fields

Setting

Version

V3

Username

SNMP V3 Username

Authentication Protocol

SHA (recommended)

Authentication Password

Password

Privacy Protocol

DES (recommended)

Privacy Password

Password

...

Once all fields are populated Click on the Test Access button. This will test that VSM can connect to the CUCM using the settings you have entered:

Image Added

Figure 67 - Web Portal – CUCM Test Access


Both SSH and SNMP should return success. If not, trouble-shoot the configuration.


Info
The SSH test ensures the VSM probe can connect to, and login using the account configured.



Info
The SNMP test ensures an SNMP query can be run.



Once testing is successful, click Add.